Harvia KIP60W vs Harvia KIP80B
Side-by-side specs and the circuit each needs, the numbers, not opinions.
| Harvia KIP60W | Harvia KIP80B | |
|---|---|---|
| Power | 6 kW | 8 kW |
| Current draw (240V) | 25 A | 33.3 A |
| Breaker / wire | 35A / 10 AWG | 45A / 8 AWG |
| Recommended room | 170–300 cf | 251–424 cf |
| Stone capacity | 44 lb | 44.1 lb |
| Control | wall | built-in |
| IP rating | IPX4 | IPX4 |
| Warranty | 2 yr | 2 yr |
| Price | price loading… view | price loading… view |
Prices from our Amazon cache where available; specs from each manufacturer manual.
Which should you get?
For a larger or colder room, the higher-output Harvia KIP80B has the margin; for a compact, well-insulated room the Harvia KIP60W is plenty and cheaper to run.
FAQ
Is the Harvia KIP60W or Harvia KIP80B bigger?
The Harvia KIP80B is the larger heater at 8 kW versus 6 kW, so it suits a bigger or colder room, up to about 424 cf. The smaller unit is cheaper to run and plenty for a compact, well-insulated space; there is no benefit to over-sizing a small room, it just cycles off sooner.
Do the Harvia KIP60W and Harvia KIP80B need the same circuit?
No. The Harvia KIP60W needs a 35 A circuit (10 AWG copper) and the Harvia KIP80B a 45 A circuit (8 AWG), because they draw different current. Size the circuit for whichever you actually buy, and remember a long run may bump the wire up a gauge.